| Solid Structures |
Unimar offers a series of standard red light controllers for chimneys, stacks, grain elevators, and other solid structures. Red lighting operates only at night; dual systems are available for those who want to use a white strobe system for daytime and still use red lighting at night (red lighting is the most widely accepted means of obstruction lighting). Our red lighting systems are designed and manufactured to provide stable long life in a rugged environment. Encapsulated solid state devices, high current operator switches, mercury contactors, boost transformers and versatile alarm relays are packaged into a controller which will provide you with security, and hassle free operation far into the future.
|
Unimar offers a series of standard red light controllers
for chimneys, stacks, grain elevators, and other solid structures. Red
lighting operates only at night; dual systems are available for those
who want to use a white strobe system for daytime and still use red
lighting at night (red lighting is the most widely accepted means of
obstruction lighting).
Our red lighting systems are designed and manufactured to provide stable
long life in a rugged environment. Encapsulated solid state devices,
high current operator switches, mercury contactors, boost transformers
and versatile alarm relays are packaged into a controller which will
provide you with security, and hassle free operation far into the
future.
|
STANDARD RED LIGHT CONTROLLERS (SOLID)
|
Class
|
Height min / max
|
VAC
|
Part #
|
Controller Description |
|
A-0
|
0 - 150'
(0) (46)
|
120
|
10001-001
|
(1 to 4) 116 Watt Single Side-Lights or 1 Double Obstruction
Light (w/ Spare Lamp) |
|
|
|
|
S-150S1
|
Same As Above In Nema 4 Enclosure with Auto/Manual door
operator switch |
|
A-0
|
0 - 150'
(0) (46)
|
120
|
10001-002
|
(2 - 9) Single Side-Lights w/ 116 Watt Lamps |
|
|
|
|
S-150S9
|
Same As Above In Nema 4 Enclosure with Auto/Manual door
operator switch |
|
A-0
|
0 - 150'
(0) (46)
|
230
|
10002-001
|
(1 to 4) 100 Watt Or 116 Watt Single Side-Lights Or 1 Double
Obstruction Light (w/Spare Lamp) |
|
|
|
|
S-150S2
|
Same As Above In Nema 4 Enclosure with Auto/Manual door
operator switch |
|
A-1
|
151' - 225'
(46) (69)
|
120
|
S-225D1
|
3 Top Beacons w/620 Watt Lamps & 3 Double Side-Lights
w/116 Watt & Spare Lamps; In Transfer Mode |
|
A-1
|
151' - 350'
(46) (107)
|
120
|
S-350D1 *
|
3 Top Beacons (*) w/620 Watt Lamps & 3
Double Side-Lights w/116 Watt & Spare Lamps; In Transfer
Mode |
|
A-1
|
151' - 350'
(46) (107)
|
230
|
S-350D2
|
3 Top Beacons w/500 Watt Lamps & 3 Double Side-Lights
w/100/116 Watt & Spare Lamps; In Transfer Mode |
|
A-2
|
351' - 450'
(107) (137)
|
120
|
S-450D1 *
|
3 Top (*) & 3 Mid Elevation Beacons w/620 Watt Lamps &
2 Elevations Of 3 Double Side-Lights w/116 Watt Lamps |
|
A-2
|
351' - 700'
(107) (213)
|
230
|
S-700D2
|
3 Top & 3 Mid Elevation Beacons w/500 Watt Lamps & 2
Elevations Of 3 Double Side-Lights w/100/116 Watt Lamps |
|
|
Over 700'
(213)
|
|
Custom
|
SEE "CUSTOM LIGHTING GUIDE" for all other options - |
DUAL LIGHTING SYSTEMS
|
A-1
|
151' - 225'
(46) (70) |
120
|
D-225S1 |
Top Level Red Beacon (Night ) / White Strobe (Day ) Mid Level
- 3 Single 116 Watt Side-Light |
|
A-1
|
151' - 350'
(46) (107) |
120
|
D-350S1 * |
Same As Above - With Boost |
|
A-1
|
151' - 350'
(46) (107) |
230
|
D-350S2 |
Top Level Red Beacon (Night) / White Strobe (Day) Mid Level -
3 Single 100 Watt Side-Light. Red Mode Is Backed Up By White
Strobe In Night Mode |
NOTE (*):
FOR ELEVATIONS OF BEACONS ABOVE 230 FT. (754m) VOLTAGE BOOST
TRANSFORMERS ARE USED WITHIN THE CONTROLLER. SPECIFY TOTAL HEIGHT OF
STRUCTURE WHEN ORDERING. #8 AWG Cu CONDUCTOR(S) ARE TO BE USED IN THE
BEACON CIRCUIT WIRING ON THE STRUCTURE RISER FOR PROPER VOLTAGE DROP
CALCULATION.
| Associated Hardware |
| p/n 18001-001 |
Photo Control 120 VAC |
......... red light |
| p/n 18002-001 |
Photo Control 230 VAC |
......... red light |
| p/n 18001-006 |
Photo Control 120 VAC |
..... strobe light |
| p/n 18002-006 |
Photo Control 230 VAC |
..... strobe light |
NOTE: ALL 120 vac controllers have been upgraded to include
Flasher Fail and Power Fail.
......... these options are available on 230 vac controllers .........
These controllers completely support the FAA and FCC requirements for
obstruction lighting.
ALSO:
......... ALL BEACONS ALARM RELAYS WILL SUPPORT 700 WATT LAMPS
.........
| |
|
|
 |
|
|
 |
|
|
| > |
Adobe Acrobat is required in order to view PDF documents |

|
|
|